7.5 Activating/deactivating safeguard function in case of wrong input

If protection at wrong input is activated, the system is locked for 30 seconds (after 5 wrong inputs
or 20 wrong subsequent characters). This applies to master and user codes.
Safeguard in case of wrong input is deactivated in the factory settings.
Input example:
*
MMMM MMMM
51 XX #
You may also specify after which errors the safeguard is to be activated.
Input example:
*
MMMM MMMM
53 0 #
*
MMMM MMMM
53 1 #
If safeguard has been activated, the factory setting for the safeguard is using 20 wrong subse-
quent characters.
7.6 Programming/change of „Aux Out" (9)
The factory setting is no password for "Aux Out" relay contacts (9).
Proceed as follows:
Input example:
*
MMMM MMMM
40 code #
7.6.1 Setting the switching duration for „Aux Out" (9)
You can define the switching duration of the „Aux Out" (9) relay contacts.
The factory setting for the switching duration is 00 (=activation until the AUX password is ente-
red).
Proceed as follows:
Input example:
*
MMMM MMMM
58 TTT #
22
Explanation
Activating/Deactivating the safeguard function in case
of wrong input
Explanation
Code lock is locked for 30 seconds after 20 wrong sub-
sequent characters.
Code lock is locked for 30 seconds after 5 wrong code
inputs (master or user code).
Explanation
code = new password for activating "Aux Out" (9);
(4-8 characters)
Explanation
TTT = 001-999 seconds
TTT = 000 Activation until AUX password isentered