6.2 Connection

1) "REED" Jumper
This jumper must be removed when a door ma-
gnet contact is connected to the "REED" con-
nection.
2) "REED", "Al-Out (-)" Connection
Reed:For connecting a door magnet contact
NC).
Al Out (-): For connection of a visual or acoustic
alarm signal; max. 12 V/DC, 500 mA.
3) LED
4) COMJoint
earth connection for REED and PB
5) "PB" Connection
An NO button can be connected here. It can
trigger the "Lock Out" relay contacts. (=door
opener function)
6) "12~24 V AC/DC" Connection
Connection for voltage supply
7) "SYSTEM RESET" Jumper
You may restore the default settings with this
jumper.
8) Internal Alarm Signal
9) "Aux Out" Relay Contacts
NO, COM, NC; suitable for connection to diffe-
rent safety systems;
max. 12 V (AC/DC), 3 A
10) "Lock Out" Relay Contacts
NO: For fail-secure(NO) door openers
COM: Joint reference point
NC: For fail-safe(NC) door openers
Door opener max. 24 V (AC/DC), 3 A