Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

Important Hints

• DO not use mineral oil on flared part.
• Prevent mineral oil from getting into the system as this would reduce the lifetime of the units.
• Never use piping which had been used for previous installations. Only use parts which are delivered with the
unit.
• Do never install a drier to this R410A unit in order to guarantee its lifetime.
• The drying material may dissolve and damage the system.
• Incomplete flaring may cause refrigerant gas leakage.
Cut
exactly at
right
angles
Connecting the Refrigerant Pipe
1. Use torque wrenches when tightening the flare nuts to prevent damage to the flare nuts and gas leaks.
Coat here with refrigeration oil
• Align the centres of both flares and tighten the flares and tighten the flare nuts 3 or 4 turns by hand. Then
tighten them fully with the torque wrenches.
• To prevent gas leakage, apply refrigeration oil on both inner and outer surfaces in the flare. (Use refrigeration
oil for R410A.)
Gas side
9K/12K
3/8 inch
31-35 Nm
Renove
burrs
Wrench
Indoor unit tubing
Flare nut tightening torque
18K
1/2 inch
50-55 Nm
Flaring
R410A tool
Clutch-type
0-0.5 mm
Open-end
wrench (fixed)
Flare nut
connection
pipe
Liquid side
9K/12K/18K
1/4 inch
15-20 Nm
Normal tool
Clutch-
Wing-nut
type
type
1.0-1.5 mm
1.5-2 mm
48