ETTL Modes
A+B+C All three groups fire at an average of the total calculated output.
A:BC Groups A and B can be set by Flash Ratio (see below). Group C is inde-
pendent with its flash output level assigned by the camera.
The EV compensation of Groups A and B can be adjusted.
1. Press the
button after exiting the Flash Ratio Setting Screen.
2. Press the
or
A and B.
3. The EV compensation for Group C can also be adjusted.
4. Pressing the
button after setting the flash ratio will move the high-
lighted selection to EV adjustment for Group C.
5. Press the
or
A:B Groups A and B can be set by Flash Ratio (see below). Group C is not
adjustable and does not fire.
The EV compensation of Groups A and B can be adjusted.
1. Press the
button after exiting the Flash Ratio Setting Screen.
2. Press the
or
A and B.
Setting and Adjusting Ratio Modes
ETTL Modes
1. Press and hold the
2. Pressing the
and
flash, Master without flash, Slave, OS and Off modes.
3. Select Master with flash or Master without flash.
4. Pressing
button will change the highlighted selection from Master
to Channel and Ratio.
5. Select the transmission channel.
6. Select the Ratio mode. Pressing the
between A+B+C, A:B and A:BC modes.
7. When A:B or A:BC are highlighted pressing the
the ratio adjustment selection below the ratio.
8. Pressing the
button will change the ratio from 1:1 to 1:8 in steps of
1:1.5, 1:2, 1:3, 1:4, 1:6, 1:8.
9. Pressing the
button will change the ratio from 1:1 to 1.5:1, 2:1, 3:1,
4:1, 6:1, 8:1.
10. Press the
button to confirm and exit the screen.
Manual Modes
A+B+C In manual mode all three groups fire at the same output level. This
power level can be set.
A:B:C The output level of each group is individually adjusted by the user (see
below). Each group is independent, one not affecting the other.
A:B Groups A and B power level can be set individually by the user (see be-
low). Group C is not adjustable and does not fire.
Setting and Adjusting Manual Modes
1. Press the
button to change the flash into Manual (M) Mode.
2. Press and hold the
10
buttons to adjust up or down EV for Groups
buttons to adjust the EV for Group C.
buttons to adjust up or down EV for Groups
button for 2 seconds to enter wireless mode.
buttons will cycle between Master with
and
buttons will cycle
button will highlight
button for 2 seconds to enter wireless mode.
INSTRUCTION MANUAL
En
3. Pressing the
and
flash, Master without flash, Slave, OS and Off modes.
4. Select Master with flash or Master without flash.
5. Pressing
button will change the highlighted selection from Master
to Channel and Ratio.
6. Select the transmission channel.
7. Select the Ratio mode. Pressing the
between A+B+C, A:B and A:B:C modes.
8. Press the
button to confirm and exit the screen.
9. Press the
button to adjust power levels.
10. Pressing the
or
(1/1 to 1/128 in 1/3rd stops).
11. Pressing the
button will change the Groups from A to B to C,
the
button from C to B to A (if applicable).
12. Press the
button to exit power level adjustment mode.

Multi Mode

A+B+C All three groups fire in Multi Mode at the same power level, frequen-
cy and flash count.
A:B:C The output level of each group is adjusted individually by the user (see
below). The frequency and flash count of the multi strobe of each group are
same and can only be adjusted on Group A.
A:B Groups A and B can be set by power level individually by the user (see
below). The frequency and flash count of the multi strobe of Groups A and
B are same and can only be adjusted on Group A. Group C is not adjustable
and does not fire.
Setting and Adjusting Multi Mode
1. Press the
button to change the flash into Multi Mode.
2. Press and hold the
button for 2 seconds to enter wireless mode.
3. Pressing the
and
flash, Master without flash, Slave, OS and Off modes.
4. Select Master with flash or Master without flash.
5. Pressing
button will change the highlighted selection from Master
to Channel and Ratio.
6. Select the transmission channel.
7. Select the Ratio mode. Pressing the
between A+B+C, A:B and A:B:C modes.
8. Press the
button to confirm and exit the screen.
9. Press the
button to adjust power levels.
10. Pressing the
or
(1/1 to 1/128 in 1/3rd stops).
11. Pressing the
buttons will change the Groups from A to B to C,
the
button from C to B to A (if applicable), and allow power level to
be changed on these groups.
12. Pressing the
button after cycling through the groups will move to
the frequency and flash count selections.
13. Pressing the
or
frequency and flash count. These setting can only be changed on Group A
and will be applied to Group B or C (if applicable).
14. Press the
button to exit power level adjustment mode.
buttons will cycle between Master with
and
buttons will cycle
buttons will change the Flash Power Level
buttons will cycle between Master with
and
buttons will cycle
buttons will change the Flash Power Level
buttons will allow changes to be made to

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis