Herunterladen Inhalt Inhalt Diese Seite drucken

Multi Mode - Phottix Mitros+TTL Benutzerhandbuch

Elektronenblitz für canon
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 18
Setting and Adjusting Ratio Modes
ETTL Modes
1. After entering OP Tx (Master) mode (above) press the
the OP Tx (Master) parameters.
2. Press the
button Three times to highlight the ratio area.
3. Select the Ratio mode. Pressing the
between A+B+C, A:B and A:BC modes.
4. When A:B or A:BC are highlighted pressing the
the ratio adjustment selection below the ratio.
5. Pressing the
button will change the ratio from 1:1 to 1:8 in steps of
1:1.5, 1:2, 1:3, 1:4, 1:6, 1:8.
6. Pressing the
button will change the ratio from 1:1 to 1.5:1, 2:1, 3:1,
4:1, 6:1, 8:1.
7. Press the
button to confirm and exit the screen.
Manual Modes
A+B+C
In manual mode all three groups fire at the same output level. This
power level can be set.
A:B:C
The output level of each group is individually adjusted by the user (see
below). Each group is independent, one not affecting the other.
A:B
Groups A and B power level can be set individually by the user (see below).
Group C is not adjustable and does not fire.
Setting and Adjusting Manual Modes
1. After entering OP Tx (Master) mode (above) press the
change the flash into Manual (M) Mode.
2. Press the
button to edit the OP Tx (Master) parameters.
3. Press the
button three times to highlight the ratio area.
4. Pressing the
and
and A:B:C modes.
5. Press the
button to confirm and exit the screen.
6. Press the
button to adjust power levels.
7. Pressing the
or
(1/1 to 1/128 in 1/3rd stops).
8. Pressing the
button will change the Groups from A to B to C, the
button from C to B to A (if applicable).
9. Press the
button to exit power level adjustment mode.

Multi Mode

A+B+C
All three groups fire in Multi Mode at the same power level, frequency
and flash count.
button to edit
and
buttons will cycle
button will highlight
button to
buttons will cycle between A+B+C, A:B
buttons will change the Flash Power Level
INSTRUCTION MANUAL
En
A:B:C
The output level of each group is adjusted individually by the user (see
below). The frequency and flash count of the multi strobe of each group are
same and can only be adjusted on Group A.
A:B
Groups A and B can be set by power level individually by the user (see
below). The frequency and flash count of the multi strobe of Groups A and B
are same and can only be adjusted on Group A. Group C is not adjustable and
does not fire.
Setting and Adjusting Multi Mode
1. After entering OP Tx (Master) mode (above) press the
change the flash into Multi Mode.
2. Press the
button to edit the OP Tx (Master) parameters.
3. Press the
button three times to highlight the ratio area.
4. Select the Ratio mode. Pressing the
between A+B+C, A:B and A:B:C modes.
5. Press the
button to confirm and exit the screen.
6. Press the
button to adjust power levels.
7. Pressing the
or
(1/1 to 1/128 in 1/3rd stops).
8. Pressing the
button will change the Groups from A to B to C, the
button from C to B to A (if applicable), and allow power level to be
changed on these groups.
9. Pressing the
button after cycling through the groups will move to
the frequency and flash count selections.
10. Pressing the
or
frequency and flash count. These setting can only be changed on Group A
and will be applied to Group B or C (if applicable).
11. Press the
button to exit power level adjustment mode.
button to
and
buttons will cycle
buttons will change the Flash Power Level
buttons will allow changes to be made to
13

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis