Light intensity varies from site to site, therefore it is recommended
that a re-calibration be performed at the time of the installation.
All direct natural sun light must be shaded from the HydroTap,
during the calibration. This can be achieved by closing any nearby
curtains, blinds and so on.
Safety sensor calibration
1. Shield the HydroTap from any
direct sun light e.g. using a dark
cloth.
2. Bring the unit in normal operating
mode.
3. Turn the power OFF.
4. Pull both tap levers to the forward
position.
5. Turn ON the power.
6. The unit will calibrate the safety
switch automatically.
7. Return the levers to the neutral
position.
Safety Sensor Calibration
Pull both levers
forward
20
Safety
sensor