Never clean seals and nozzle or air holes of the spray gun with metal objects.
The seal parts are only solvent-resistant to a limited extent. Do not immerse in solvent, only wipe.
Fig.8
Maintenance
Change the air filter if it is soiled (Fig. 9).
How to change nozzles:
Please always unplug the power cord.
1. Unscrew and take out the union nut. Remove the air cap and current nozzle.
2. Cover the air cap onto the new nozzle.
3. Pull the trigger and insert the second nozzle with air cap onto the front part (pay attention to align the boss
on the nozzle to the slot on the device) then screw back the union nut.
Correction of Malfunctions
Problem
Nozzle clogged
Feed tube clogged
No coating material
Material volume setting turned too far to the
emerges from the
downside (-)
nozzle
Suction tube loose
No pressure build-up in container
Viscosity of coating material too high
Nozzle loose
Coating material
Nozzle worn
drips from the
Coating material assembly at air cap, nozzle or
nozzle
needle
Release button
Reason
Fig.9
Filter
Solution
Clean
Clean
Turn to the upside (+)
Insert
Tighten container
Thin
Tighten
Change
Clean
GB