Clean the device with a damp cloth only. Do not use a cleansing agent as this
may damage the plastic.
Problem
Drive is not functioning. Faulty connection.
Blind or shutter moves
in the wrong direction.
The UCS520 does not
carry out the external
commands.
Manual commands are
not executed.
Nominal voltage
Switched current
System of protection
Protection class
Permissible ambient temperature
Running time awning
Running time Venetian blinds
Type of installation

Cleaning

What to do if...?

Cause
Faulty connection.
The UCS520 is in manual
mode.
The alarm signal is on.

Technical data

230240 V AC / 5060 Hz
5 A /250 V AC for cos ϕ =1
IP 20
II In accordance with the assembly
specifi cations
0 to +55 °C
2 min
3 min
Concealed Ø 58 mm wallmounted.
Exposed in appropriate exposed casing.
Remedy
Check connection.
Exchange  and  wires
in the power supply unit.
Set the UCS520 to auto-
matic mode.
Wait until the alarm signal
disappears or switch
it off.