Water level alarm
Inhaltsverzeichnis

Werbung

Failure: The green "Level" LED (1) is lit; neither
sensor indicates a failure. However, the units
connected up to the switched socket outlet do
not operate.
Cause: The fuse in the switched socket outlet is
damaged due to overload.
Remedy: Reduce the load on the switched socket
outlet. The switched socket outlet can be loaded
up to a resistive load of 1,800 W, but with motors
only to approx. 900 W at 230 V (450 W at 115
V). Call an authorised electrician to replace the
fuse: type T 8A.
Cause: The cable connection from the switched
socket outlet to the PCB is loose.
Remedy: Check the cable connection on the
controller 7607/2; connect the plugs tightly.
Cause: The switched socket outlet is defective.
Remedy: Have the switched socket outlet replaced
or repaired.
Disfonctionnement: La LED verte (1) «Level»
est allumée, aucun capteur ne signale de défaut,
pourtant les appareillages raccordés à la prise
commandée ne fonctionnent pas.
Raison: Le fusible placé dans la prise commandée
est défectueux en raison d'une surcharge.
Solution: Réduisez la charge de la prise
commandée. Cette charge est de 1.800 W en
puissance ohmique mais seulement de 900 W
en puissance de moteurs (450 W en 115 V). Le
remplacement du fusible type T 8A ne doit être
entrepris que par un électricien.
Raison: Le raccord de la prise commandée est
déconnecté de la platine.
Solution: Vérifiez le raccordement dans le Controller
7607/2, appuyez fortement sur la prise.
Raison: La prise commandée est défectueuse.
Solution:
Remplacez
prise
commandée.Inbetriebnahme