The following NRPN messages can be received.
NRPN
Data Entry*1
MSB
LSB
MSB
LSB
01H
08H
mm
– *2
01H
09H
mm
01H
0AH
mm
– *3
01H
20H
mm
01H
21H
mm
01H
63H
mm
01H
64H
mm
01H
66H
mm
*1 See 1.2.3
*2 "–" means that the set value will be ignored.
*3 Adjusts the time after the note is played until vibrato begins to take effect.
The effect will begin more quickly for lower values, and more slowly for
higher values.
1.2.15 RPN (Registered parameter number)
This message is used to specify part parameters such as Pitch Bend Sensitivity or
Tuning. Use RPN MSB and RPN LSB to specify the parameter that you wish to
modify, and then use Data Entry (see 1.2.3) to set the value of the specified
parameter.
Control#
Parameter
100
RPN LSB
101
RPN MSB
If the Multi Part parameter Rcv RPN = OFF, that part will not receive this mes-
sage.
The following RPN messages can be received.
RPN
Data Entry*1
MSB
LSB
MSB
LSB
00
00H
mm
–*2
00
01H
mm
ll
00H
02H
mm
7FH
7FH
*1 Refer to 1.2.3
*2 "–" means that the set value will be ignored.
1.2.16 Assignable controller
By assigning a control change number of 0...95 to a part, application of effects
can be controlled. This device allows two control change numbers (AC1 and
AC2) to be specified for each part.
The following parameters specify the effect of AC1 and AC2:
* Multi Part Parameter
1. AC1, AC2 PITCH CONTROL
2. AC1, AC2 FILTER CONTROL
3. AC1, AC2 AMPLITUDE CONTROL
4. AC1, AC2 LFO PMOD DEPTH
5. AC1, AC2 LFO FMOD DEPTH
6. AC1, AC2 LFO AMOD DEPTH
The AC1 control change number is specified by the Multi Part parameter ACl
CONTROLLER NUMBER, and the AC2 control change number is specified by
the Multi Part parameter AC2 CONTROLLER NUMBER.
AC1,AC2 AMPLITUDE CONTROL is processed on the host device (e.g.,
MOTIF, MU128, 9000Pro, etc.)
Parameter Name and Data Range
Vibrato rate
mm: 00H - 40H - 7FH (-64 ...0...+63)
Vibrato depth
mm: 00H - 40H - 7FH (-64 ...0...+63)
Vibrato delay
mm: 00H - 40H - 7FH (-64 ...0...+63)
Low pass filter cutoff frequency
mm: 00H - 40H - 7FH (-64 ...0...+63)
Low pass filter resonance
mm: 00H - 40H - 7FH (-64 ...0...+63)
EG Attack Time
mm: 00H - 40H - 7FH (-64 ...0...+63)
EG Decay Time
mm: 00H - 40H - 7FH (-64 ...0...+63)
EG Release Time
mm: 00H - 40H - 7FH (-64 ...0...+63)
Data Range
0 ... 127
0 ... 127
Parameter name and value range
Pitch bend sensitivity
mm: 00-18H (0...+24 semitones)
Specify up to 2 octaves in semitone steps
Fine tuning
mm ll: 00H 00H -100 cents
:
:
mm 11: 40H 00H 0 cents
:
:
mm ll: 7FH 7FH +100 cents
Note: The next after mm 11: 00H 7FH
(= -87.5) cent is 01H 00H (-87.4) cents.
Coarse tuning
mm: 28H - 40H - 58H
(-24...0...+24 semitones)
RPN Null
This empties settings from RPN and
NRPN numbers.
Internal data is not affected.
1.3 Channel mode messages
These messages specify the basic operation of a part.
1.3.1 All Sound Off
This message silences all notes being played on the corresponding channel.
However, channel messages such as Note-on and Hold-on will be maintained in
their present state.
Control#
Parameter
120
All Sound Off
1.3.2 Reset All Controllers
This message changes the settings of the following controllers.
Controller
Pitch bend change
±0 (Center)
Channel pressure
0 (OFF)
Polyphonic key pressure
0 (OFF)
Modulation
0 (OFF)
Expression
127 (Max.)
Hold
0 (OFF)
Portamento
0 (OFF)
Sostenuto
0 (OFF)
RPN
Number unset, internal data is not affected.
NRPN
Number unset, internal data is not affected.
The following data is not changed
Parameter values specified for program change, bank select MSB/LSB, volume,
pan, RPN and NRPN.
Control#
Parameter
121
Reset All Controllers
1.3.3 All Note Off
This message turns off all notes which are currently on for the corresponding
part.
However, if Hold 1 or Sostenuto are on, notes will continue to sound until these
are turned off.
Control#
Parameter
123
All Note Off
1.3.4 Omni Off
Works the same as when All Note Off is received.
Control#
Parameter
124
Omni Off
1.3.5 Omni On
Works the same as when All Note Off is received.
Control#
Parameter
125
Omni On

1.4 Program change

This message is used to switch voices.
It changes the program number on the receiving channel. When the change is to
include the voice bank, transmit the program change after sending the Bank
Select message (see 1.2.1).
If the Multi Part parameter Rcv PROGRAM CHANGE = OFF, that part will not
receive program changes.

1.5 Pitch bend

This message conveys information on pitch bend operations.
Basically, this message is for changing the pitch of a part, but the depth of the fol-
lowing six effects can be controlled.
The effect of this message can be modified by the following parameters.
* Multi Part Parameter
1. BEND PITCH CONTROL
2. BEND FILTER CONTROL
3. BEND AMPLITUDE CONTROL
4. BEND LFO PMOD DEPTH
5. BEND LFO FMOD DEPTH
6. BEND LFO AMOD DEPTH
By default, the Pitch Control effect is applied.
If the Multi Part parameter Rcv PITCH BEND CHANGE = OFF, that part will
not receive pitch bend messages.
BEND AMPLITUDE CONTROL is processed on the host device (e.g., MOTIF,
MU128, 9000Pro, etc.)
MIDI Data Format
Data Range
0
Value
Data Range
0
Data Range
0
Data Range
0
Data Range
0
61