Commissioning
The decoder is supplied with power via
◆
the connection of the drive.
No separate power supply can be
◆
connected.
In analog mode, a continuous voltage must be
◆
applied to the usual track connection. The
switching then takes place via K1 and K2 by
connecting them to ground or GND.
The motor runs for a maximum of the time
◆
set in CV23 as the emergency shutdown time.
This should be longer than the actual driving
time. The
decoder measures the current of the motor, with
When reaching an end position, the motor
switches off when the switch-off current in
CV24 is reached. Generally, this value does
not need to be adjusted unless the travel time is
very short, in which case it may be necessary
to reduce the value. The driving speed is
specified in CV22 as the motor dimming value.
Power supply
Voltage range
9-24V
◆
Protocols
DCC
◆
Märklin Motorola
◆
Power requirement
Quiescent current below 10mA
◆
The current requirement of the output
◆
depends on the connected drive. Motor
approx. 10mA
6