Configuratio
n
Output 1
Relay output as changeover sel circuit
Feature
CV
Address
40
Address
41
Switching
42
time
Switching time
The switching time can be set individually.
◆
If the switching time is set to 0, the
◆
selected output remains activated until the
other output is selected.
If the switching time is set to a value greater
◆
than 0, the relay only switches to green for the
duration of the switching time.
Outputs
Default
4
0
0
Possible
Meaning
values
0-255
8 LSB
0-7
3 MSB
0-255
Switching time in seconds
Example of continuous operation
Switching time is 0
◆
The green command on the control panel
◆
switches the relay to the green output.
The relay remains green until the control
◆
panel switches back to red.
Example switching pulse
Switching time is 10
◆
The green command on the control panel
◆
switches the relay to the green output.
After 10 seconds, the relay
◆
automatically switches back to
output red.
9