Configuratio
n
Output 1
Relay output as changeover sel circuit
Feature
CV
Address
40
Address
41
Switching
42
time
Switching time
The switching time can be set individually.
If the switching time is set to 0, the
selected output remains activated until the
other output is selected.
If the switching time is set to a value greater
than 0, the relay only switches to green for the
duration of the switching time.

Outputs

Default
4
0
0
Possible
Meaning
values
0-255
8 LSB
0-7
3 MSB
0-255
Switching time in seconds
Example of continuous operation
Switching time is 0
The green command on the control panel
switches the relay to the green output.
The relay remains green until the control
panel switches back to red.
Example switching pulse
Switching time is 10
The green command on the control panel
switches the relay to the green output.
After 10 seconds, the relay
automatically switches back to
output red.