Code
Problem
E5
Temperature fuse defect.
E6
Water level too high and
operation not permitted.
E7
Water level too low and
operation not permitted.
E8
Illogical combination of
water level measurements.
E9
Fill failure
E10
Drain failure
E11
Communication failure.
E12
Temperature is greater than
the maximum temperature.
E13
No master steam generator
connected
Check the wire between the fuse and the control
unit. Fuse has probably overheated. The reason
for overheating must be discovered before using
the steam generator again. A new fuse is
needed.
If no problem can be found, contact the retailer.
Check that the drain valve is not blocked.
Clean the level probes. If no problem can be
found, contact the retailer.
Check that water supply is open and there is
enough pressure. Check solenoid valve.
Clean level probes. If no problem can be
found, contact the retailer.
Clean level probes. If no problem can be
found, contact the retailer.
Check that water supply is open and there is
enough pressure. Check solenoid valve.
Clean level probes. If no problem can be
found, contact the retailer.
Check that the drain valve is connected and
not blocked. Clean the level probes. If
problem can be found, contact the retailer.
Check the RJ12 cable. If the area where
cable is located has many other cables, it
can cause EMC problems.
If no problem can be found, contact
the retailer.
Contact qualified electrician or maintenance
personnel before using the steam generator
again.
Dip switch setting is incorrect. Check dip
switch settings.
Check RJ12 for loose contact. Replace RJ12.
If no problem can be found, contact the retailer.
Solution
no
17