5. Standby Mode

Pause
Standby Mode is activated when Steam ON button is pressed or Session Time
has expired. Optional features such as Dimmer and Fan can be set at this state.
In the Standby Mode, steam room temperature will be maintained at a certain level
(refer to standby temperature setting 3.5.8.) Also water inside steam generator will
be kept hot to give user fast steam when starting steam session.
5.1 Current Day and
Standby Time

5.2 Pause Button

6. Drain Mode

Only
applicable
autodrain is enabled by the
Steam
Generator
switches (refer to page 12)
and in the Settings Menu
(refer 3.5.4).
10

Current Day and Standby Time

This button displays the remaining standby time. You can
change the standby time by pressing it. Use the up and down
arrows to change settings.
The maximum standby time is set by dip switches in the steam
generator. Refer to page 12.
Short press the pause button to switch to On Mode.
Long press it to switch to Off Mode. If autodrain is present, long
press pause button to switch to Drain Mode.
The autodrain feature automatically drains the water
when
after every use. The tank is flushed and will remain
empty until the steam generator is used again.
DIP
After the Standby Time expires, control unit
automatically switch to Autodrain mode. During the
drain cycle, the steam generator's tank is filled with
cold water so that the valve can be opened safely.
The draining process will take about 10 minutes. You
can press the OK button to cancel the draining.