Electrical connection

Dangerous electrical voltage!
Risk of injury due to dangerous electrical voltage!
 The machine may only be connected to the power supply and the associated
checks carried out by a qualified electrician or under the instruction and
supervision of a qualified electrician!
Check, whether the neutral connection (if existing) and the protective grounding
function properly.
Check, whether the supply voltage and the frequency correspond to the
specifications of the machine.
Deviation of the supply voltage and frequency!
A deviation from the value of the supply voltage of ±5 % is permissible.
A short-circuit fuse must be provided in the power supply system of the machine!
Use a supply cable that fulfils the electrical requirements (e.g. H07RN, H05RN) and
take the required cross-section of the supply cable from a current carrying capacity
table. Pay attention to the measures for protection against mechanical damage.
Make sure that the power supply is protected by a residual current circuit breaker.
Connect the machine only to a properly grounded outlet.
When using an extension cable, make sure that the dimension matches the
connected load of the machine. The connection power can be found in the technical
data, the correlation of cable cross-section and cable lengths can be found in the
technical literature or obtain information from a specialist electrician.
A damaged cable must be replaced immediately.
Operation is only permitted with residual current device (RCD) with maximum
residual current of 30 mA.
ZIPPER MASCHINEN GmbH
5. Centering cone
• Slide a cone (1) and the clamping cover (2) onto the
6. Assembled machine
W A R N I N G
www.Zipper-Maschinen.at
threaded shaft (4) and loosely tighten the quick release
nut (3).
N O T E
N O T E
ASSEMBLY
28
ZI-RWM99O
Inhaltsverzeichnis
loading

Inhaltsverzeichnis