3.
INSTALLATION
THE BURNER MUST BE INSTALLED IN CONFORMITY WITH LEGISLATION AND LOCAL STANDARDS.
3.1
WORKING POSITION
The burner is programmed to operate only in positions 1 and 2.
Installation 1 is to be preferred since it is the only position where maintenance can be carried out as de-
scribed in this manual.
With installation 2, operation is ok but maintenance cannot be carried out with the burner hooked to the boiler.
Any other installation would affect the burner operation.
Installations 3, 4 and 5 are forbidden on safety grounds.
1
3.2
BOILER FIXING
To fit the burner to the boiler it is necessary to carry out the following:
Put on the flange (1) the screw and two nuts, (see fig. 3).
Widen, if necessary, the insulating gasket holes (4).
Fix the flange (1) to the boiler door (3) using screws (5) and (if necessary) the nuts (2) interposing the
insulating gasket (4), (see fig. 2).
After installation ensure that burner is lightly inclined as in fig. 4.
Fig. 2
Fig. 3
3280
2
3
4
4
S7071
GB
5
D7088
D5025
Fig. 4