The floor should be firm and completely level. Reposition the heater, when it is
not level. Do not correct the situation by placing books or other goods under the
heater. Please refer to the separate instructions in the carton box for fixing of
the heater.
6
Your heater is now ready for use.
B

FILLING FUEL

Fill the removable tank in a suitable place since there can always be some spillage.
Follow the procedure below:
1
Make sure that the heater is switched off.
2
Open the upper lid and lift the removable tank out of the heater (Fig. G).
Note: Some drops may leak from the tank. Put down the removable tank (cap
pointing upwards, handle on floor and screw off the fuel cap.
3
Fill the removable tank using a fuel pump (refer to fuel pump operation
instructions.) Make sure that it is in a higher position than the removable tank
(Fig. H). Insert the ribbed hose into the opening of the removable tank.
4
Check the removable tank fuel gauge while filling the tank (Fig. I). Stop filling
once the gauge indicates that the tank is full. Never overfill the tank, especi-
ally not when the fuel is very cold (fuel expands when it heats up).
5
Let the remaining fuel in the pump flow back into the jerry can and carefully
remove the pump. Carefully screw the fuel cap back on the tank. Clean off
any spilled fuel.
6
Check whether the fuel cap is straight and tightened properly. Reinstall the
removable tank in the heater (cap down). Close the lid.
C
IGNITING THE HEATER
A new heater may give off some smells for a short while, when it is used for the
first time. You should therefore provide extra ventilation or ignite the heater
outside the living room.
When you use the heater for the first time, first put the filled removable tank into
place, and then wait approximately 30 minutes before you ignite the heater. This
allows the glass fibre wick to soak up the fuel. Follow the same procedure when you
have completely burnt up all fuel from the tank, and after the glass fibre wick has
been replaced.
Before igniting the heater, always check the fuel indicator F to see whether the
removable tank needs filling up.
Always ignite the heater with the ignition coil K. Never use matches or a cigarette
lighter.
Follow the procedure below:
1
Turn the knurled wick adjustment knob 2 clockwise to its stop (Fig. K). If you
apply more pressure you may turn it slightly further; however, it will automati-
cally return to the startposition.