Connecting RTS 40 to accessory card
In those cases RTS 40 is to be used for climate system 2,
3 or 4, it is connected electrically to the accessory card
(AA5-X2:19-20).
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
-X8
-X2
-X4
1
2
3
4
5
6
7
8

Program settings

Program setting of RTS 40 can be performed via the start
guide or directly in the menu system.
Start guide
The start guide appears upon first start-up after heat
pump installation, but is also found in menu 5.7.
Menu system
If you do not make all settings via the start guide or need
to change any of the settings, this can be done in the
menu system.
Menu 1.1 - temperature
Setting the indoor temperature.
Menu 1.9.1 - heating curve
Setting the heat curve.
Menu 1.9.2 - external adjustment
Setting external adjustment.
Menu 1.9.4 - room sensor settings
Activating and setting the room temperature sensor.
Caution
Also see the Installer manual for
F1126/F1226/F1145/F1245.