Electrical connection
NOTE
All electrical connections must be carried out by
an authorised electrician.
Electrical installation and wiring must be carried
out in accordance with the stipulations in force.
F1126/F1226/F1145/F1245 must not be powered
when installing RTS 40.
Use cable type LiYY, EKKX or similar with a cable
area of at least 0,5 mm².
F1126/F1226
Connecting RTS 40 to heat pump
Terminal block X1 in F1126/F1226 has soft inputs/outputs,
which means you can set the function for the terminal
block's different inputs.
1. Enter menu 5.4 and select which inputs on the ter-
minal block the room temperature sensor should be
connected to.
2. Connect the room temperature sensor to the selected
inputs on terminal block X1.
F1126
F1226
Example:
F1145/F1245
Connecting RTS 40 to heat pump
In those cases RTS 40 is to be used for climate system 1,
it is connected electrically to the input card (AA3-X6:3-4)
in F1145/F1245.
F1145
F1245