Herunterladen Diese Seite drucken

Victron energy BP40 Gebrauchsanweisung Seite 4

Batteryprotect
Vorschau ausblenden Andere Handbücher für BP40:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Specifications:
Auto detect 12 or 24V Battery voltage
8-20V
->
20-35V
->
10 programmable voltage thresholds
Over voltage shut down
> 16V
(12V mode)
> 32V
(24V mode)
Current in use ~ 4mA
Current in OFF position or under- or over-voltage position
Maximum Load (shut down current)
BP40
:
BP60
:
BP200
:
Peak current
BP40 & BP60
BP200
Shut down at overload after 5 sec. (after 1 minute start up)
Connections
ON/OFF switch
Alarm buzzer or relay
CurrentWatch current sensor
Voltage drop
BP40
:
BP60
:
BP200
:
Voltage tolerance
Current output tolerance +/- 20%
Water proof
The BP will shut down after about 5 seconds when overloaded. After about 60 seconds the BP will start up again.
Programming table
12 Volt mode
Undervoltage
Threshold
Position 1
Position 2
Position 3
Position 4
Position 5
Position 6
Position 7
Position 8
Position 9
Position 10
Position 11
Normal Alarm
Position 12
Relay function
Position 1 & 11 Default positions
Normal alarm: Alarm output activated at alarm; deactivated after 1 minute.
Relay function: Alarm output activated at alarm; deactivated at overvoltage threshold.
12V mode
24V mode
~ 40A (45A)
~ 60A (65A)
~ 200A (210A)
:
120A
:
480A
~ 0,0875 @35A
~ 0,125 @ 50A
~ 0,1125 @ 180A
~2%
IP66
Uppervoltage
Threshold
10,5V
10 V
9,5V
11,25 V
11,5V
10,5V
11,5V
11,8 V
12 V
10 V
_
~ 2mA
CurrentWatch
(Optional)
24 Volt mode
12 V
Position 1
11,5V
Position 2
11,5V
Position 3
13,25 V
Position 4
13,8 V
Position 5
12,8 V
Position 6
12,8 V
Position 7
12,8 V
Position 8
13 V
Position 9
13.2 V
Position 10
Position 11
Position 12
BatteryWatch
(Optional)
FUSE
+
Input+
+
Sense
Alarm
Buzzer
_
Undervoltage
Threshold
21 V
20 V
19 V
22,5 V
23 V
21 V
23 V
23,6 V
24 V
20 V
Normal Alarm
Relay function
_
+
BG40/60
Output+
Output+
BG200
ON/OFF
(Closed=OFF)
Uppervoltage
Threshold
24 V
23 V
23 V
26,5 V
27,6 V
25,6 V
25,6 V
25,6 V
26 V
26.4 V
4 - BG.070227