Victron energy BP40 Gebrauchsanweisung Seite 3

Batteryprotect
Vorschau ausblenden Andere Handbücher für BP40:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BP200
:
Spanningsnauwkeurigheid
Stroom nauwkeurigheid +/-20%
Waterdicht
IP66
Programmeer tabel
12 Volt mode
Onderspanning
Positie 1
Positie 2
Positie 3
Positie 4
Positie 5
Positie 6
Positie 7
Positie 8
Positie 9
Positie 10
Positie 11
Normale Alarmering
Positie 12
Relais functie
Position 1 & 11 Standaard instelling.
Normaal alarm : Alarm uitgang wordt geactiveerd in geval van alarm; deactivatie na 1 minuut
Relaisfunctie: Alarm uitgang wordt geactiveerd in geval van alarm; deactivatie bij het bereiken van de bovenspanning.
Read the owners manual carefully before installing the BP!
Owners manual BP40 / BP60 / BP200
The new Battery Protect BP40/60/200 (hereafter called BP) is an intelligent, waterproof, Battery Protect with accessory connections for a ON/OFF
switch, Alarm buzzer or relay and our CurrentWatch current sensor (not included). The unit has two bolts as connection for the Input+ and the
Output+ to guarantee low losses. Other connections, like the minus and the accessories, are made by a 4-pole 6.3mm faston connector. A blue LED
shows the status (ON/OFF). In program- mode it shows the program position. The BP has an 'Automatic system voltage Detection'; the BP detects
which battery voltage (12 or 24V) is used. This does not need to be programmed manually. There is a choice of 10 on/off threshold voltages, for both
12V and 24V, which can be programmed in a simple way. The BP uses very little current. In the OFF mode or when in under voltage the BP uses just
2mA or less.
Installation
The installation of the BP has to be done by qualified personnel. Working with batteries is not without danger. Use wires of sufficient diameter and
connectors of good quality. All connections have to be done via a fuse of the right value. See for a guiding principle for the wire diameter the separate
chapter. Attention! Live wires should never make contact with the case of the BP or the vehicle. Wrong connection could damage the electronic circuit.
Mount the BP on a cooling (metal) surface, so it can dissipate the generated heat. Mount it as close as possible to the battery (max. 50cm). This is the
only way to exactly guard the voltage of the battery. Wait with connecting the equipment until the BP is fully programmed. Use a 1.5mm
minus connection which is directly connected to the battery. No other equipment should be connected to this wire.
Programming
To start the program mode a connection should be made between the Input+ and the ProgramInput. The LED will start flashing. The number of flashes
represents the program-position (see table) it is in. As soon as the desired program-position is reached the connection, between the Input+ and the
ProgramInput, should be removed. To confirm the programmed position the LED will repeat the number of flashes. If it is not the right position, the
previous steps have to be repeated. A change in position 11 or 12 has to be programmed separately. The programmed positions will be remembered,
even if the battery connection has been removed. After completing the programming the equipment can be connected.
ATTENTION! First remove the battery-connection, connect the equipment to the Output+ and then reconnect the battery.
Default program-position is position 1 and 11. See program table.
Remote ON/OFF
There is a possibility to connect a switch to the BP's OFF connection. If the OFF connection is connected to the Minus, the BP will shut down the
connected equipment after about 1 second. If the connection is removed, the equipment will be started up again after about 1 second. The current
through the switch is very low, so a small switch can be used.
Alarm-output
A buzzer can be connected to the alarm-output. The buzzer/alarm will be activated in case of under voltage after about 12 seconds. When there is no
change in this situation the BP will shut down the equipment about 90 seconds later. The buzzer/alarm will also be stopped. Because at overvoltage
(16V/32V) the equipment can be damaged, the BP will shut down the equipment immediately and the alarm-output will pulsate. This way you can hear
the difference between an under voltage and an over voltage alarm. A second application of this output is with the use of a relay. In this application the
BP should be programmed in program-position 12 (default is position 11) . This way the relay will be activated at alarm and when it reaches the upper
voltage threshold it will be deactivated again. This way the relay can be used to activate a charger or generator.
CurrentWatch
The Prog/Current connection can be used to connect a CurrentWatch. The CurrentWatch will show the current used by your equipment. If you are
interested in this product, please contact your supplier.
Wire cross section
Use at least the following wire cross section for the bolt connection:
BP40 min 10mm
2
BP60 min 15mm
2
BP200 min 50mm
2
In difficult environments it is advised to use larger cross sections.
ca. 0,1125 @ 180A
ca.2%
Bovenspanning
10,5V
10 V
9,5V
11,25 V
11,5V
10,5V
11,5V
11,8 V
12 V
10 V
24 Volt mode
Positie 1
12 V
Positie 2
11,5V
Positie 3
11,5V
Positie 4
13,25 V
Positie 5
13,8 V
Positie 6
12,8 V
Positie 7
12,8 V
Positie 8
12,8 V
Positie 9
13 V
Positie 10
13.2 V
Positie 11
Positie 12
Onderspanning
21 V
20 V
19 V
22,5 V
23 V
21 V
23 V
23,6 V
24 V
20 V
Normale Alarmering
Relais functie
Bovenspanning
24 V
23 V
23 V
26,5 V
27,6 V
25,6 V
25,6 V
25,6 V
26 V
26.4 V
2
wire for the
7-BG.070227