Herunterladen Inhalt Inhalt Diese Seite drucken

Terminal Assignment For Version; Input Functions - Hengstler signo 721 Benutzerhandbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

4.4.1 Terminal assignment for version

721 101/121
• 1 preset
• relay output
• 12-24 V DC =
1
DC
Power
+
2
DC
supply
3
NC
4
NC
5
NC
6
30 V DC =/1 A
7
OUT
250 V AC ~/1 A
8
max. 250 V
9
O V
10
Sensor V DC - 2 V/60 mA
11
Input
12
Reset
13
Appl.*
14
Keylock
15
PSC-Out
16
NC
721 102/109/122
• 1 preset
• relay output
• 100-240 V/24 V AC ~
1
AC~
Power
2
AC~
supply
3
NC
4
NC
5
NC
6
30 V DC =/1 A
7
250 V AC ~/1 A
OUT
8
max. 250 V
9
O V
10
Sensor 24 V DC =/ 60 mA
11
Input
12
Reset
13
Appl.*
14
Keylock
15
PSC-Out
16
NC
721 103
• 1 preset
• transistor output
• 12-24 V DC =
1
DC –
Power
2
DC +
supply
3
NC
4
NC
5
0 V
6
NC
7
OUT
V DC –2 V
0 V
8
/20 mA
9
O V
10
Sensor V DC - 2 V/60 mA
11
Input
12
Reset
13
Appl.*
14
Keylock
15
PSC-Out
16
NC
721 104
• 1 preset
• transistor output
• 100-240 V AC ~
1
AC ~
Power
2
AC ~
supply
3
NC
4
NC
0 V
5
6
NC
7
OUT
24 V DC =
0 V
8
/20 mA
9
O V
10
Sensor V DC - 2 V/60 mA
11
Input
12
Reset
13
Appl.*
14
Keylock
15
PSC-Out
16
NC
* See next column – Application Input
18/24
P2
721 105/125
• 2 presets
• relay output
• 12-24 V DC =
1
DC
Power
+
2
DC
supply
3
NC
4
OUT1
30 V DC =/1 A
5
250 V AC ~/1 A
6
NC
max. 250 V
7
OUT2
8
9
O V
Sensor V DC - 2 V/60 mA
10
11
Input
12
Reset
13
Appl.*
14
Keylock
15
PSC-Out
16
NC *
P2
721 106/110/123/126
• 1 presets
• relay output
• 100-240 V/48 V AC ~
1
AC~
Power
2
AC~
supply
3
NC
4
OUT1
30 V DC =/1 A
5
250 V AC ~/1 A
6
NC
max. 250 V
7
OUT2
8
O V
9
Sensor 24 V DC =/ 60 mA
10
11
Input
12
Reset
13
Appl.*
14
Keylock
15
PSC-Out
16
NC *
P2
721 107
• 2 presets
• transistor output
• 12-24 V DC =
1
DC –
Power
2
DC +
supply
3
NC
OUT1
V DC –2 V
4
0 V
5
/20 mA
6
NC
7
OUT2
V DC –2 V
8
0 V
/20 mA
9
O V
10
Sensor V DC - 2 V/60 mA
11
Input
12
Reset
13
Appl.*
14
Keylock
15
PSC-Out
16
NC *
P2
721 108
• 2 presets
• transistor output
• 100-240 V AC ~
1
AC
Power
2
AC ~
supply
3
NC
OUT1
24 V DC =
4
0 V
/20 mA
5
6
NC
7
OUT2
24 V DC =
8
0 V
/20 mA
O V
9
10
Sensor V DC - 2 V/60 mA
11
Input
12
Reset
13
Appl.*
14
Keylock
15
PSC-Out
16
NC *

4.4.2 Input functions

The active level/edge of the inputs depends on the position of switch
1 (pnp-Input/npn).
Switch position pnp
Input
level high
count
reset
gate/display hold
keylock
locking
up/down
adding
Input
level high
count
reset
gate/display hold
keylock
locking
up/down
adding
Count input (Input)
The count input (terminal 11) is controlled by the active edge
Max. counting frequency is 5 kHz. Commercial electronic pulse
generators (high level > 8 V, npn/pnp output) may be used as well as
potential-free switches in conjunction with the proper voltage. The
level must not exceed 40 V!
Reset input (Reset)
Depending on the position of switch 9, the count is either set or reset
by feeding an active level to the reset input (terminal 12).
Note
• As long as an active signal is supplied to terminal 12 the
correction value cannot be modified via keyboard!
• The setting/resetting characteristic of the counter is static, i. e.,
incoming pulses will not be counted as long as the reset input is
activated.
Outputs OUT1 and OUT2 are deleted by a keypad reset or external
reset.
Remainder values resulting from the multiplication with the prescaler
value which are not indicated are deleted during each reset.
Application Input (Appl.)
The application input (terminal 13) can be used for three different
functions.
• Find the Item No. of your counter on the type plate of the
appliance.
• Determine the function defined by the Item No. from the table at
the end of this chapter.
0 721 101 ... 110
Gate (Inhibit)
Depending on the position of switch 2 the count input (terminal
11) will be disabled (switch position ON) or enabled (switch posi-
tion OFF) by feeding the active level to the gate input (terminal
13).
This function allows the counting operation to be specifically in-
terrupted when continuous count pulses are present at the
count input.
Sach-Nr. 2 721 091; Version 1250100MW
unconnected
level low
input
deactivated
deactivated
deactivated
released
not locking
subtracting
subtracting
unconnected
level low
input
deactivated
deactivated
deactivated
released
locking
subtracting
adding
.