Problem
Steam too wet
Insufficient or no steam
The blowing air is insufficient.
The fan motor does not work.
The waistband and hem tension is
insufficient.
The slide does not stop when moving
down.
The toothbelt makes noise
Error message
ERROR 1: U.REED/MOTOR
ERROR 2: B.REED/MOTOR
ERROR 3: EEPROM SAVE
ERROR 4: EEPROM READ
ERROR 5: MOTOR/CURRENT
16.02.2010
Cause
The stop valve of the condensate drain is
closed.
The supply is dirty.
The steam nozzle is dirty.
The steam valve is defective.
The timer is defective.
The fluff filter is dirty.
The impeller is dirty.
The potentiometer is defective.
The phase control is defective
(Art.No.487315000 0).
The motor contactor is defective.
The air pressure is too low.
The micro switch is defective.
Friction between tooth belt and tooth
wheel
Cause
No signal from upper reed sensor.
Magnet on the slide doesn't reach the
upper reed.
No signal from bottom reed sensor.
Magnet on the slide doesn't reach the
bottom reed.
Fail to save some values to memory
Fail to read some values from memory
No current flows to the motor.
Current detector cable short circuited to
the ground or not connected to the main
board
Hosentopper VEIT 8741
VEIT 8741 Pants Finisher
Troubleshooting
Open the stop valve.
Clean or replace it.
Clean or replace it.
Replace it.
Replace the PC-board.
Clean it.
Clean it.
Replace it.
Replace it.
Replace it.
Increase the pressure on the maintenance
unit.
Check the switch and the cable; replace, if
necessary.
Spray Silicon Spray on the tooth belt
Troubleshooting
Check the distance of upper between reed
sensor and the magnet. Adjust it if too far.
Replace defective reed. Replace defective
servo motor.
Check the distance of bottom between
reed sensor and the magnet. Adjust it if
too far. Replace defective reed. Replace
defective servo motor.
Restart the machine. If recurrence,
replace the Controller/Processor.
Restart the machine. If recurrence,
replace the Controller/Processor.
Check the motor and wiring. Replace
defective servo motor.