Installation
Procedure:
1.
Pull out closing bracket
2.
Loosen two screws
The timer PCB will receive power from incoming 24 Volt DC cables (red and
black).
3.
Cut the red
about 10 mm of the insulation from both ends.
SON053438 Rev 2-09.2025
1
(right or left side) and open dispenser front cover.
1
2
1
of the product funnel and pull out funnel
2
2
1
and black cable
that are installed in the housing and remove
1
2
4
closing bracket
1
funnel
1
funnel screw connection
2
24 volt DC cable (red)
1
24 volt DC cable (black)
2
upwards.
2