Herunterladen Diese Seite drucken

roco zimo Betriebsanleitung Seite 8

In rocolokomotive

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

When operated with a conventional transformer, the
locomotive performs like a locomotive without a
decoder. However, the locomotive will begin to move
only after a control voltage of 5 to 5.5 Volts (DC) or
8 to 8.5 Vots (AC) has been reached, because the
decoder requires a certain minimum voltage simply
to operate. Sound functionality is possible during
analogue operation and begins at approx. 4.5V
(DC) or 6.5V (AC).
– In DC operation trouble-free running with pulse-
width or phase-control controllers cannot be guar-
anteed.
– In AC operation the control knob is turned to the
left through the zero position as usual to change
the running direction: keep the regulator knob
pressed down for about half a second to ensure
that the reversing command has been reliably
GB
identified! The locomotive should first have
come to a standstill in every case.
Activate or deactivation the desired sound functions
via the CV13/CV17 (only possible with a digital
system).
Possible Settings in DCC Digital
The most important CV's
For the preset factory values please see the informa-
tion sheet enclosed with the locomotive or decoder.
Notice:
For the Lokmaus
values from 0 – 99 are programmable.
For the multi MAUS, the CV's from 1 – 256 and the
corresponding values from 0 – 255 are program-
mable.
CV
1
2
3
4
5
6
7
8
13
8
Analogue Operation
Operation
®
, the CV's and the corresponding
Adress
(= short Adress)
Starting voltage
(lowest creep speed)
Acceleration time
(from standing to maximum speed)
Braking time
(from maximum speed to full stop)
Maximum speed
Average speed
(by middle driving stage)
Decoder Version Number
(only read! Readable only on rea-
ding-capable amplifiers/centres)
Reset Function
(Returns all values to the factory set-
tings; the manufacturer's ID is rea-
dable on reading-capable amplifiers/
centres)
Analogue Modes F1-F8
(
00 – no function in analogue mode)
01 – Function F1 02 – Function F2
04 – Function F3 08 – Function F4
16 – Function F5 32 – Function F6
64 – Function F7 128 – Function F8
Attention! Several things happen at
the same time when several functions
are activated via CV's in analogue
operation.
value
01 – 99
01 – 252
00 – 255
00 – 255
00 – 252
00 – 252
00 – 255