2.7 Battery Warning
WARNING
• KEEP NEW OR OLD USED BATTERIES OUT OF REACH OF CHILDREN.
• In the event of a battery leaking, do not allow the liquid to come into contact with the skin or eyes. If contact has
been made, wash the affected area with copious amounts of water and seek medical advice immediately.
WARNING: Battery not replaceable. See instruction manual.
3 Introduction of Functions
3.1 Test Mode
SC01/SC07/SC08: The Test/Silence button is used to test the unit's electronics and to silence the unit during an alarm.
When testing the alarm weekly, you should first wake up your alarm by pressing the test button; once the alarm has
woken up, the LCD display will activate, then press and hold the test button again until you hear a short beep,
indicating that the alarm has entered the test mode. The alarm goes back to the standby mode after testing. To save
power, the alarm is designed to automatically turn off the LCD display if there has been no operation for 5 minutes.
SC03/SC06: The Test/Silence button is used to test the unit's electronics and to silence the unit during an alarm.
When testing the alarm weekly, press and hold the test button until you hear a short beep, indicating that the
alarm has entered the test mode. The alarm goes back to the standby mode after testing.
Note: After a test has begun, the alarm will sound and the LED indicator will flash red. This does not indicate that
smoke/CO is present.
3.2 Alarm Mode
CO Alarm Levels
This X-Sense carbon monoxide alarm is programmed to sound an alarm at the following CO concentrations within
the periods listed:
50 ppm for 60–90 minutes,
100 ppm for 10–40 minutes,
300 ppm for < 3 minutes.
1. If the Alarm Is Triggered by Smoke:
When the device detects smoke, the unit will beep 3 times every 4 seconds, paired with the LED flashing red.
2. If the Alarm Is Triggered by CO:
When the device detects CO, and the CO ppm reaches a certain level for a while, the unit will beep 4 times every
5.8 seconds, paired with the LED flashing red.
When the smoke or CO concentration drops below the alarm threshold, the alarm sound will stop, and the LED will
flash green once every second for 5 seconds. Then, it will automatically enter standby mode.
10
3.3 Silence Mode
Smoke Silence Mode: Press the test button during an alarm to have the unit enter silence mode. If the smoke
concentration has reached an alarm level, after the silence time has expired, this unit will continue to alarm until the
smoke concentration decreases to a safe, low level. Otherwise, the alarm will enter the normal mode after 9 minutes.
CO Silence Mode: Press the test button during an alarm to have the unit enter silence mode. If the CO density still
exceeds the alarm threshold after 6 minutes, the unit will re-enter alarm state. Otherwise, the unit will exit the
silence mode after 9 minutes and resume normal operation.
Note: If the CO concentration is above 300 ppm, the silence function cannot be enabled.
WARNING
• Any remote silencing function can only be used within the line of sight of the CO alarm.
• If there is any doubt about the cause of the alarm, it should be assumed that the alarm was triggered by dangerous
levels of carbon monoxide, and the residence should be evacuated.
3.4 Low-Battery Mode
The LED indicator will flash yellow together with one beep every 60 seconds.
THE UNIT MUST BE DEACTIVATED (see "Deactivation of the Alarm" section) AND REPLACED AS SOON AS POSSIBLE.
If you press the test button when there is low battery, the low battery signal will temporarily cease for 10 hours.
3.5 Fault Mode
When the device sensor fails (including sensor open circuit and short circuit), the LED will flash yellow twice every
60 seconds, accompanied by two alarm sounds.
The fault code E04 indicates a short circuit, while E03 indicates an open circuit.
3.6 End-of-Life Mode
Once the maximum lifetime (10 years) is reached, the alarm will deliver 3 beeps and the LED indicator will flash yellow 3
times every 60 seconds. This end-of-life signal can be temporarily silenced for 22 hours by pressing the test button.
The end-of-life silence feature can only be used for a total of 30 days. After 30 days, the end-of-life signal cannot be silenced.

4 Daily Maintenance

To keep your smoke/CO alarm in good working order, follow these simple steps:
1. Verify the unit's alarm sound and indicators are working properly by testing the unit once a week.
2. Remove the unit from the ceiling/wall and clean the alarm cover and vents with a soft brush attachment once a
month to remove dust and dirt.
3. Never use detergents or other solvents to clean the unit.
4. Avoid spraying air fresheners, hair spray or other aerosols near the alarm.
5. Do not paint the unit. Paint will seal the vents and interfere with the sensor's ability to detect smoke or CO. Never
attempt to disassemble the unit or clean inside. Doing so will void your warranty.
6. When removed, place the smoke/CO alarm back in its proper location as soon as possible, to assure continuous
protection from fire or carbon monoxide poisoning.
7. When household cleaning supplies or similar contaminants are used, the area should be
WARNING: DO NOT TAMPER WITH THE APPARATUS, AS THERE IS A RISK OF ELECTRIC SHOCK OR MALFUNCTION.