en - Original instructions
Application examples
All connections with external power supply are optional.
It can use the HRI's internal battery.
forward
meter index
backwarts
l1 (balanced)
open
close
EN
l1 (forward)
open
close
l2 (backwards)
open
close
l1 (forward & backwards)
open
close
l2 (direction)
open
forward
close
PLC with switched
ground
HRI with external
power supply
PLC with
switched
HRI
power
A4
supply
B4
TR100 (829372)
Remote display
This application can
be also used as a
test tool for all HRI
types
Connection with
CDL
5 Technical data
• Temperature range
Storage: -20 °C to +65 °C
Operation: -10 °C to +65 °C
• Cable length: 1.5 m
• Hermetically sealed housing IP 68
• EMC acc. EEC directive 98/34 equal European
standards EN61000-6-1
6 Pulse-outputs (I1/I2) all types
Open drain transistor switch according ISO/TC30
Vmax: 24V DC / Imax: 20mA / Pmax: 0,48VA / fmax:
5Hz
Max. voltage by closed switch: 0.3V + I * 260 Ω
If the data interface isn't used the serial resistance
can be reduced by 150 Ω with the connection of
green and brown wire.
4
Flow
Mode A4, B1, B4
Mode B2
Mode A3 / B3
forward
backwards
green
HRI
+24 V
pulse
A4
unit
B4
white
brown
green
white
1kΩ
brown
forward
forward
white
88888888
count 20 HZ
HRI
backwards
(B2)
yellow
88888888
count 20 HZ
only with A2/B2
brown
brown
yellow
HRI
white
(A3)
soldering side
plug
Meter
HRI-A
DN
A4
15-40
A3
15-40
HRI-B: Pulse length 124 ms fixed, Flow direction
(A3/B3) signal l2 is 18μs prior to I1
Operational cable length up to 10 m
Transient voltage protection is highly recommended
for wiring outside buildings.
7 Data interface (HRI-Bx only)
M-Bus and MiniBus (Auto speed detection:
300/2400 Baud)
Protocol according EN13757-3 equal IEC 870 / EN
1434-3
Data: meter ID, meter index (optional 1 litre or 1 m3
resolution)
Operational cable length: according to M-Bus speci-
fication.
PLC
With M-Bus reading is unlimited, with MiniBus the
reading shouldn't be more than 5 times per day to
avoid a battery lifetime of less than 10 years.
With the data interface the following values can
be set via MiniCom (version >3.0); standard setting
+24V
from the factory in brackets:
• Primary address (0)
• Secondary address (HRI-Fabrication No.)
• Meter ID No. (HRI-Fabrication No.)
0V
• Meter index (0); if the aluminium foil is missing,
index can be different
• Pulse mode (according the order)
0V
• Pulse weight (according the order)
Attention: The resolution of meter index can't be
changed, so this setting must be correctly defined
with the order.
If the HRI is ordered mounted on top of a meter, the
secondary address, meter ID no. and meter index
are preset with the meter's values. Setting on site
isn't necessary.
If data interface and pulse output is used at the
same time, potential free connection for the connect-
ed devices are requested. During data communica-
tion pulse lost is possible depending on the pulse
collector's input circuit.
8 End-of-life product disposal
Handle and dispose of all waste in compliance with
local laws and regulations.
EU and UK only: Correct disposal of this
product — waste electrical and electronic
equipment
• EU: Directive 2012/19/EU on waste electrical and
electronic equipment (WEEE)
• UK: SI 2013 No. 3113
Pulse weight (length)
D1
D10
D100
(124ms)
(500ms)
(500ms)
1l
10l
100l
1l
----
----