Environmental
NOTE:
For additional information about environmental measurements for specific
system configurations, see www.dell.com/environmental_datasheets
Temperature
Operating
Storage
Relative humidity
Operating
Storage
Maximum vibration
Operating
Storage
Maximum shock
Operating
Storage
10° to 35°C (50° to 95°F) with a maximum
temperature gradation of 10°C per hour
NOTE:
For altitudes above 2950 feet, the
maximum operating temperature is derated
1°F/550 ft.
–40° to 65°C (–40° to 149°F) with a
maximum temperature gradation of 20°C
per hour
20% to 80% (non-condensing) with a
maximum humidity gradation of 10%
per hour
5% to 95% (non-condensing) with a
maximum humidity gradation of 10%
per hour
0.26 Gms from 5–350 Hz for 5 minutes
in operational orientations
1.54 Gms from 10–250 Hz for 10 minutes
in all orientations
Half sine shock in all operational orientations
of 31 G plus or minus 5% with a pulse
duration of 2.6 ms plus or minus 10%
Half sine shock on all six sides of 71 G plus or
minus 5% with a pulse duration of 2 ms plus
or minus 10%
Square wave shock on all six sides of 27 G
with a velocity change at 235 in/sec or greater