2. Remove the dust reservoir from the motor section. Then take the filters out of the dust
reservoir. Pull it towards you by the handle.
3. Empty the dust reservoir. Pull the HEPA filter out of the filter holder. The dust container, filter
holder (B), and HEPA filter (A) may be cleaned under running water. Do take care to dry them
completely before using them again in the machine.
4. Put the dry filters back in the dust container. Put the dust container back in the hand-held
vacuum: first put the top back in position and then click the bottom into place.
1
I
We advise replacing the filters regularly to ensure an optimal operation of the machine. Dirty
filters will reduce the suction power drastically. After every cleaning, clean the dust reservoir
and the filters to extend the life span of your machine.
CLEANING THE FLOOR BRUSH
1. Remove the floor nozzle from the upright vacuum cleaner. Press the release button at the back
of the floor nozzle and remove it from the machine.
2. Slide up the release on the right side of the floor nozzle and simultaneously remove the
rotating floor brush from the floor nozzle. Use the tab to do this.
3. Gently remove any hair and dirt from around the brush; do this by hand or carefully with a
knife.
4. The rotating floor brush may be rinsed off under running water. Make sure that it is completely
dry before using it.
5. To refit the brush, place the left side of the brush against the gear (a) and push the right side (b)
until it clicks into place.
6. Push the nozzle back onto the stick. The machine is now again ready for use.
1
I
Stuck hairs can damage the machine or your floor. Always remove the hairs stuck on the
brushes.
2
3
2
www.domo-elektro.be
A
B
5
a
b