Table 1-1. System Messages
Message
The FBD link to the
following DIMM failed to
train: DIMM x
FBD training error - The
following memory branch
has been disabled:
Branch x
LCD Status Messages Update
Table 1-2 lists updates to the LCD status messages that can occur and the probable cause for each
message. The LCD messages refer to events recorded in the system event log (SEL). For information
on the SEL and configuring system management settings, see your systems management software
documentation.
Table 1-2. LCD Status Messages
Code
Text
CPU Temp Interface The BMC is unable to determine
E1118
0.9 V Over Voltage 0.9 V regulator voltage has exceeded
E122B
E122C
CPU Power Fault
NOTE:
Each diagnostic LCD message is assigned a priority. The highest priority messages supersede any group
of messages with a lower priority.
4
Information Update
Causes
An error has occurred on the FBD
channel that contains the specified
DIMM. A fault is indicated on the
link adjacent to the DIMM caused
by a faulty condition in either the
specified DIMM, the next DIMM
in the channel, or possibly the
system board. When this error
occurs, the other FBD branch in the
memory pair is disabled, resulting in
the second error message.
Causes
the CPU(s) temperature status.
Consequently, the BMC increases
the CPU fan speed to maximum
as a precautionary measure.
the allowable voltage range.
A voltage regulator failure was
detected when the processor
regulator(s) was enabled.
Corrective Actions
Reseat all of the DIMMs on the
indicated FBD channel. See
"Memory" in the Hardware Owner's
Manual for information about the
FBD branches and channels. See
"Troubleshooting System Memory" in
the Hardware Owner's Manual. If the
problem persists, see "Getting Help"
in the Hardware Owner's Manual.
Corrective Actions
Turn off power to the system and
restart the system. If the problem
persists, see "Getting Help" in the
Hardware Owner's Manual.
See "Getting Help" in the
Hardware Owner's Manual.
See "Getting Help" in the
Hardware Owner's Manual.