Digital Laser Measure
Measuring accuracy (typical under unfavourable
conditions)
Lowest indication unit
Indirect Distance Measurement and Vial
Measuring range
Inclination measurement
Measuring range
Measuring accuracy (typical)
Lowest indication unit
General
Operating temperature
Storage temperature
Relative air humidity, max.
Laser class
Laser type
Laser beam diameter (at 25 °C) approx.
– at 10 m distance
– at 50 m distance
Automatic switch-off after approx.
– Laser
– Measuring tool (without measurement)
Weight according to EPTA-Procedure 01:2014
Dimensions
Degree of protection
Batteries
Rechargeable batteries
Battery life, approximately
– Individual measurements
– Continuous measurement
Setting the unit of measure
Data transmission
Bluetooth®
1 609 92A 23J | (25.8.16)
GLM 50 C
±3.0 mm
0.1 mm
0°–360° (4x90°)
0°–360° (4x90°)
C)/D)/I)
±0.2°
–10 °C...+45 °C
–20 °C...+70 °C
635 nm, <1 mW
9 mm
45 mm
5 min
0.10 kg
106 x 45 x 24 mm
IP 54 (dust and splash proof)
2 x 1.5 V LR03 (AAA)
2 x 1.2 V HR03 (AAA)
10000
2.5 h
m, ft, in
Bluetooth® 4.0 (Classic and
Low Energy)
Bosch Power Tools
B)
0.1°
E)
90 %
2
D)
D)
20 s
H)
F)
H)
H)
G)

Werbung