36YH56000.book 9 ページ 2014年8月28日 木曜日 午後1時41分
3.Connect the discharge hose.
Use the hose connector, hose band and a commercially available
discharge hose. A short, large-diameter hose is most efficient. Long or
small-diameter hose increases fluid friction and reduces pump output.
NOTE:
Tighten the hose band securely to prevent the hose from disconnecting
under high pressure.
DISCHARGE PORT
HOSE CONNECTOR
HOSE COUPLING
HOSE COUPLING
PACKING
HOSE BAND
DISCHARGE HOSE
(Commercially available)
HOSE CLAMP
RING
9