Display
• When power on the refrigerator for the 1st time, the whole dispaly panel will shine
for 3 seconds. Then the dispaly panel enters the normal display. Open door display
light on; When the door closes, the display light goes out.The first time for using the
refrigerator, the default set temperatures of refrigerating chamber is 5°C.
• When the error occurs, the display panel shows the error code. Otherwise, the
display panel shows the set temperature.
EN
Temperature setting
• Press the temperature up button "Λ" can adjust the temperature, each click of the
temperature up button "Λ", the set temperature will be rised 1°C; Press the
temperature down button "∨" can adjust the temperature,each click of the
temperature down button "∨", the set temperature will be reduced 1°C; The
temperature setting range of refrigerating chamber is 2~8°C. When the temperature
is adjusted to the boundary value, the refrigerator will sound an alarm if the
temperature up button "Λ" or the temperature up button "∨" still have been
pressed.
Set the mode
• Set the Super cooling mode: after the temperature of the refrigeration room is
adjusted to 2°C, press the temperature down button "∨" to enter the super cooling
mode. In the super cooling mode, the temperature of the refrigerating chamber is
automatically set to 2°C.
• Exit the Super cooling mode: press the temperature up button "Λ" to exit the
super cooling mode or automatically exit the super cooling mode after 6h. After
exiting the super cooling mode, the temperature of the refrigerator will
automatically return to the temperature set before the super cooling mode.
Opening alarm control
• If the door is not closed in two minutes, the buzzer will sound untill the door is
closed. Press any one button to stop the buzzer alarm.
Temperature adjustment can exit from the rapid cooling mode