TOSHIBA
INSTALLATIONMANUAL
Accessory parts
No.
Part Name
Remote
Wood
1 controller
3
Screw
Installation
2 w x 20
4 Manual
2
Remote controller
installation
Installation
lace
Install the remote controller
1 - 1.5m above floor level (average room
temperature area).
Do not install the remote controller in a place exposed to direct sunlight or
outside air (such as a window, etc.).
Do not install the remote controller where ventilation is poor.
Do not install the remote controller in a freezing or refrigerated
remote controller is not water or splash-proof.
Install the remote controller in a vertical position.
Remote
controller
installation
dimension
Besuretofollowtheinstallation d imension (Fig. 1 )
as Shownin the figure 1 when you install
the remote
controller
on the wall.
(mm)
How to install
the remote
NOTE I : The remote
controller
wire should
not be bundled
(mains. etc.), or Installed with other wires in the same conduit, as
malfunction
may result.
NOTE 2: Install the remote controller away from sources of electrical interference
and electromagnetic fields.
NOTE 3: If electrical interference is unavoidable, countermeasures
appropriate filtering should be ernployed.
Wood screws
Remote
Cover
<Remote controller (Rear):.
1. For removal of the remote controllers lower case (rear case), insert the tip of
a flat head screw driver, etc., into the two openings at the bottom of the
remote controller to open the lower case.
2. Fix the remote controller's rear case by wood screws (2 pcs.). Do not over
tighten. as it may damage the rear case.
3. Connect
the wares from the indoor
unit to the remote
(Refer to "How to wire the remote controller.)
Connect the wires of the remote controller
following
numbering convention of the indoor unit to prevent miswiring. (Do not
apply 230V AC mains voltage
to the remote controller
damaged).
To installation
Part Name
How to select the room temperature sensor
screw
2
Two room temperature
the remote controller. Only one sensor (usually the indoor uni?s) can be active at
any one time.
To select the sensor in the remote controller, perform the following steps.
Push
+ temperature setup button
NOTE: The unit number displayed the first time is the indoor unit address of
requirements
the master unit in the group control.
NOTE:Do not pressthe@NjD button
IJsingthe temperaturesetup buttons
2.
Using the timer buttons
3.
Push the
4.
area - the
constantly lit.)
Pushthe@button
5.
The status returns to the operation stop status and
LCD
120
62
NOTE I : When using two remote controllers, the room temperature sensor
selection
Only the header remote controUer can act as a remote control sensor.
When using two remote controlers,
either
NOTE 2: In group control, the remote control sensor does not work if the group
address
NOTE 3: When using the remote sensor and the remote controller together. do
not use the remote
controller
with other
wires
How to wire
Connection
diagram
Terminal
block
such as
for remote
controller wiring
Wiring slot
in indoor
unit
Lower
case
Push andholdthe(Z) button for4 seconds o rmore until " TEST' a ppears i n
(Rear case)
controller
the LCD display. then press the
"TEST' appears in LCD display during the test run.
Temperature
run applies considerable load on the machine; therefore, it is recommended
not to use the test mode beyond necessity.
2. The test mode should be used in either HEAT or COOL mode.
NOTE: The outdoor unit will not operate tor approx. 3 minutes after power up.
controller
terminal
block.
or the operation will stop.
the terminal
3.
Be sure the "TEST" indication in the LCD display has disappeared by pushtng the
button again after exiting the test mode. (The remote controller has a
as it will be
60-r•ninuteoff timer function to prevent continuous test run).
personnel
- Electrical
sensors are installed: one in the indoor unit; the other in
for 4 seconds or more.
, specifythe item code 3?.
, change the setting from nn nn
button. (The display should stop flashing and become
is displayed in the
can be set either
from the header,'f0110wer
remote
the temperature
can be set from
the header
or follower
remote
controller.
is not set to the indoor
unit of the master
unit.
control
sensor
of the rernote
controller.
the
remote
controller
• Use 0.5 to 2mmZ wire.
Remote controller Wiring
• Can not use the closed
(procured on site)
end wire joint.
Remote
controller
Remote
controller
terminal
block
• Terminals A and B arc non-polar.
Remote controller test run setup
button
adjustment
is not possible while "TEST" is displayed. The test
work and Service
Multiple remote controller installation requirements
In a dual remote controller system, one or more units are operated by multiple
remote controllers. (A maximum of two remote controllers can be set.)
Remole
controller
(inside, rear)
Follower
controller
Header
controller
How
to
install
For a dual remote controlter system. install the remote controllers in the following
1. Set one ot remote controllers as the header remote controller. (The default
setting is 'Header.')
2. Set the DIP switch on all other remote controller P.C. boards to Sub (to enable
them as follower remote controllers).
Basic wiring diagram
NOTE:
Terminals
A and
B are
non-polar
Operating one indoor unit from
remote
controllers
installed
in
controller.
two different
locations.
Operating a group control ot multiple indoor units from remote controllers
installed
in two different
locations.
• Header and Follower remote controllers
connected to any indoor unit.
Remote
controller
(Header)
Terminal
block tor
remote controller . F
wire
inch-or ur%t
NO-I
Earlh
When a remote controller
is used for the first time, initial operation atter power on
will take a tew moments.
This is not a malfunction.
<lnitial power on period>
Allow approx. 5 minutes for the remote controller to operate.
"SETTING"
Power on
flashing
<UsuaI power on period after the second time>
Allow approx. I minute for the remote controller to operate.
"SETTING"
Power on
flashing
Standard
Wired
Remote
Controller
Model:
RBC-AMT31E,RBC-AMT32E
Header remote
Follower
remote
controller
controller
remote
remote
Be sure to set
switch
2 to the
lower POSItion
Remote controller
Remote controller
Foiiower
Header
separaten
Remote
controller
wires
Terminal
block for
(procured on
remote controller winng
site).
Jroor
urut
Earth
are operable
even if they are
Remote
controller
(Follower)
Remote
controller
Inter•unit
wtres
(see
for group control
sepuateiy)
(procured on site)
Indoor
unit
unit
Indoor
unn
No.2
Earth
No.3
NO.8
Requirement
Appro,
Sminutes
"SETTING"
off
1 minute
"SETTING"
Complete
ott