Installation when operating with tripod / mast systems
INFORMATION!
• The luminaire can be operated on various tripod / mast systems.
A mast mount is available on the luminaire for this purpose. The
mount is suitable for a DIN bolt (d = 30 mm, as spare part, item
no. 1410960018W).
• The luminaire may only be operated in connection with a tripod /
mast system which is equipped with a standard pin according to
DIN 14640.
• Operation of the luminaire is only permitted up to a maximum
wind speed of 100 km/h. The prerequisite is that the wind direction
is constant, that weighting elements are used and that the ground
is flat and firm. Safe operation cannot be guaranteed in stronger
winds.
ATTENTION!
• Make sure the tripod / mast system can support the weight of the luminaire. For safe operation, the instructions
for the tripod / mast system must be observed.
• The ALDEBARAN® CLS PRO (CONSTRUCTION LIGHT SYSTEM Professional) requires room / ambient air for
proper operation. The luminaire must be installed free-standing with at least 0.5 m clearance on all sides.
WARNING! Risk of injury!
• When operating with a tripod or mast, it must also be ensured that this is sufficiently stable. It is important to ensure
that it is on a level surface. Inclinations are to be avoided.
• Be sure to fix the luminaire with the star grip after it has been placed on your tripod / mast system. This is how you
avoid accidents.
• The tripod has a pinch and pull-out protection.
• If the locking screw is not tightened, the push rod may retract automatically under the load.
• An unsafe stand of the tripod endangers persons and material in the vicinity. Wind load or impact can cause the
tripod to fall over.
• When loosening the wing bolt and retracting, always hold the retracting push rod firmly. Do not stand under moun-
ted equipment (e. g. headlights etc.) when retracting. As soon as the first push rod retracts, the bracing set loses its
effect, take note of this and, if necessary, take suitable measures beforehand to secure the tripod during retraction.
Fault
Light module(s) without function
Three adjacent light modules without
function
All six light modules without function No voltage
WARNING! Electric current!
Before any maintenance, cleaning and care, the device must always be disconnected from the power supply by
pulling the mains plug.
16
Fault
Possible cause
Defect in the light module
Pressure switch OFF
Solution
Repair necessary
Checking the controls
(pressure switch)
Check the power supply