Note: If the CO concentration
has reached an alarm level, after the silence time has expired,
continue
to alarm
until
the CO concentration
decreases
Alarm
Sounder
The a arm wil sound when there isCO present, when testing the alarm, and when there isa fault.
LED
Indicator
The LED indicator wil flash in conjunction
with the alarm sounder. Therefore, it wil flash during the fol owing states:
when powering on, in standby mode, during CO alarm states, when exiting an alarm state, during test mode, when
there is ow battery, in si ence mode, when there is a fau t and when the unit is at the end of its life.
Low Battery
The LEDindicator wil flash yel ow together with one beep every 60 seconds.
THE UNIT MUST BE DEACTIVATED
(see "Deactivation
POSSIBLE.
(f you press the test button when there is ow battery, the ow battery signal will temporarily cease for 10 hours; if you
press the test button
again, the unit wil enter the test mode and then the standby mode.)
End
of Life
Once the maximum
ifetime (10 years) is reached, the a arm delivers 2 beeps and the LED indicator wi flash yel ow
twice every 30 seconds.This end of-life signal can be temporarily silenced for 3 days by pressing the test button.
The end-of- ife silence feature can only be used for a total of 30 days. After 30 days, the end-of-life signal cannot be
Different working modes and states are shown in the below table:
Mode
LED Indicator
Blinks 8 cycles
Powering on
(red/green/yel
ow) in sequence.
Flashes green once every 60
Standby mode
seconds.
this unit will
to a safe, low level.
of the Alarm"
section)
AND REPLACED
AS SOON AS
Audible
Alarm
Remarks
None.
None.
• 04 •
First 4 minutes:
flashes
red 4
times every
seconds.
After 4 minutes:
flashes red 4
times every 60 seconds.
Alarm
m Ode
Flashes g
o nce every
second
for 5 seconds.
2 sets of4
red flashes.
est
mode
Flashes red once every 5
seconds.
Si ence mode
Flashes green 3 times.
Flashes yel ow once every 60
Low battery
seconds.
Flashes
ow 1-4 times every
Fault
40 seconds.
Flashes yel ow 2 times every 30
End of life
seconds.
First 4 minutes: 4 quick beeps
every 5.8 seconds.
After 4 minutes: 4 quick beeps
every 60 seconds.
None.
Exiting an alarm: When the
CO concentration
below
the alarm threshold,
the alarm signal stops.
2 sets of 4 quick beeps.
After 9 minutes,
None.
will
exit si ence
Exiting si ence mode.
None.
One beep every 60 seconds.
2 beeps every
2 beeps every 30 seconds.
drops
the unit
mode.