These positions are a recommendation for new installations or if
there is not yet a suitable connection in the existing installation.
An exception to position '
connection in an existing installation. In that case make sure that no
splash water can get into the housing of the logger.
•
The Risycor can be installed in various ways:
a.
In an existing female 1/2" threaded connection;
b.
In a T-piece: in this case, provide a T-piece with a "female
G 1/2" thread" in the transverse leg, without an internal
strut or collar at the end of the internal thread.
•
CAUTION! T-pieces with a strut or collar could narrow the
threaded connector due to radial compression, and this in turn
could block the probe tip in the fit, which has now become too
narrow, and cause irreparable damage.
a.
In a weld socket
max. 25 mm
CAUTION! Maximum length of 25mm, probe tip must be positioned
in the flow.
•
Ensure that there is an electrical outlet nearby.
' can be made if there is already a
EN
31