2
WIRING
N
L
PE
Blue
Brown
- 3 operators (max.) can be wired in parallel on one
switch.
- Attach cables to prevent any contact with moving parts.
- If the motor is used outdoors and if the power supply cable is of the H05-VVF type, then run the cable in a
UV-resistant conduit, e.g. trunking.
- The motor can not be use with control devices such as: emergency power supply (ie: regulated power supply,
power generating unit, triac, ex, ...). Use only mechanical or electromechanical switches (e.g. relays) to
control a motor. The relay contacts must not be bypassed by capacitors.
3
POWER UP OF THE OPERATOR
>>
After the first two consecutive opening and closing of the shutter :
- The motor memorizes automatically the end limit (up and down) positions.
- The «stop on obstacle» function is activated.
It is advised to carry out these two opening/closing cycles as soon as the product is installed.
4
CANCELLING THE AUTOMATIC SETTINGS
In the case of a new installation with this operator, it is advised to reset the motor according to the
following procedure:
- Press 3 consecutive times, for 1s each time, on the UP key. The motor runs briefly at each press.
- Press 3 consecutive times on the DOWN key. The first two press for 1s (the motor runs briefly at each press)
and the third press for 2s. The motor runs twice in the same direction.
>>
>>
1 s
1 s
1 s
5
OPERATION AND MAINTENANCE
- This drive is maintenance-free.
- Press the ▲ button on the control point to raise the motorised product.
- Press the ▼ button on the control point to lower the motorised product.
Tips and recommendations for use:
PROBLEMS
The motorised product does
not operate.
If the motorised product still does not work, contact a drive and home automation professional.
We care about our environment. Do not dispose of the appliance with usual household waste. Give it to an approved
collection point for recycling.
SIMU SAS, F-70100 ARC-LÈS-GRAY as manufacturer hereby declares that the drive covered by these instructions when marked for input
voltage 230V~50Hz and used as intended according to these instructions, is in compliance with the essential requirements of the applicable
European Directives and in particular of the Machinery Directive 2006/42/EC and EMC Directive 2014/30/EU. The full text of the EU declaration
of conformity is available at www.simu.com. Bruno STRAGLIATI, Chief Executive, ARC-LÈS-GRAY, 12/2020.
T5S AUTO/T5S AUTO+
Black
Green/Yellow
>>
>>
>>
POSSIBLE CAUSES
The overheating protection on the drive has
been activated.
N
L
PE
>>
>>
>>
>>
1 s
1 s
T5S AUTO+SHORT
OK
>>
>>
>>
>>
2 s
SOLUTIONS
Wait for the drive to cool
down.
EN