EN
1) Main switch (red)
Press this switch to bring the appliance into operation. The red light lights up when the appliance is
switched on.
2) Power rocker switch with pos. 450 W / 750 W / MAX
Use this 3-position rocker switch which also serves as an economy circuit to select the power and lowest
fuse protection of 2 A.
The function is as follows:
•
450 W / 2 A - Fuse protection: For extremely small fuses and low heating requirement. Also serves as
economy circuit.
•
750 W / 4 A - Fuse protection: This position can also be selected with small fuses and also serves as
an economy circuit.
•
MAX 1500/1800 W / 6-10 A - Fuse protection: Move the switch to this position to select maximum
heating power depending on the heating requirement, or to heat quickly. The fan runs at high speed.
3) Thermostat rotary knob
You can vary the room temperature infi nitely according to the temperature scale via the thermostat.
The function is as follows:
•
Select the ice crystal symbol to set a frost protection temperature of 5 °C. The appliance can be
operated continuously during the period of frost.
•
You can select the ventilation symbol to activate a fresh air fan which delivers pleasant refreshing
air.
•
Select a comfortable temperature for you according to the temperature scale. This will be regulated
automatically.
•
As soon as temperature is reached, the heating device switches off . The fan continues rotating for
approx. 15 min.
4) PLUS rocker switch
Operate this 2-position PLUS rocker switch to increase the heating power. With this higher heating power
the fan speed increases slightly.
When switching on the 2-position PLUS rocker switch, you can see a red marking. With this position, the
heater will increase in (heating) power and the fan rotates more.
NOTE: The PLUS-function can only be chosen in 450 W and 750 W level. In MAX level it cannot be chosen.
ECOMAT2000 | 25