Appliances carrying this symbol must not be disposed of
with household waste. They must be collected separately and
recycled.
Products at the end of their life must be collected and recycled
in accordance with the local provisions and decrees.
Installing an appliance at altitude causes an increase in the
air outlet temperature (around 10 °C per 1000 m change in
altitude).
PREPARING TO INSTALL THE APPLIANCE
Installation rules
- This appliance has been designed for installation in a residential setting.
Please consult your retailer for any other scenario.
- Installation must be carried out in accordance with industry best
practice, and in compliance with the standards in force in the country of
installation (NFC l5-100 for France).
- The appliance must be connected to a 230V, 50 Hz single-phase
power supply.
- In wet environments such as bathrooms and kitchens, the connection
box must be installed at least 25 cm from the floor.
To avoid any disruption to the operation of the appliance,
ensure that it is not placed in a draught (e.g.: under a ventilation
system, etc.).
Do not install under a fixed power outlet.
Volume
2
Installation
Volume
1
Volume 1 No electrical appliances
IPX4 electrical appliance
Volume 2
(Standard EN 60335-2-
43: 2003/A2: 2008)