Menu item
Description
Device settings
Interval flush
• User-controlled: A flush is
actuated at the end of the [flush
interval], whereby the flush
interval is restarted with every
use. The flush time is
determined by the [flush time]
value.
• Interval-controlled: A flush is
actuated at the end of the [flush
interval], regardless of the
number of uses. The flush time
[Interval flush]
is determined by the [flush time]
value.
• Difference flush: A flush is
actuated at the end of the [flush
interval], regardless of the
number of uses. If flushes have
already been performed within
the [flush interval], the postflush
only makes up the difference in
[flush time].
[Flush time]
[Flush interval]
Set operation mode
• Normal operation: The tap
flushes as long as an object is in
the detection range. A [run-on
time] can be set if necessary.
[Operation mode]
• Water saver: The tap flushes as
long as an object is in the
detection range, but not longer
than the [max. flush time].
[Run-on time]
[Max. flush time]
Check detection range
Indicates when the sensor detects
a user. The sensor can be recal-
ibrated in the event of detection
faults or a change in environment.
The environment is re-evaluated in
the process.
[Detection range]
[Detection range]
[Recalibrate sensor]
Note: There must be no hands or
objects in the washbasin during
calibration.
27021606563888139 © 02-2022
970.658.00.0(00)
Application
• To fill the trap in the
case of low user
frequencies
• To flush out standing
water in the pipe
(hygiene function – to
prevent stagnation)
• To reduce the water
consumption
• In the case of problems
with user recognition
• To optimise user recog-
nition
• In the event of
detection malfunctions
• In the event of a
changed environment
(e.g. new washbasin)
Area
Factory
setting
[Off], [User-
controlled],
[Interval-
[User-
controlled],
controlled]
[Difference
flush]
1–200 s
5 s
1–168 h
24 h
[Normal
[Normal
operation] or
operation]
[water saver]
0–30 s
2 s
3–30 s
10 s
Automatic
Short to long
Medium
distance
distance [1]
[0–4]
[Start
calibration]
2 / 3
35
EN