Herunterladen Inhalt Inhalt Diese Seite drucken

Minimum Pulse; Female Male Error; Auger Status; Unit - Roxell Rdc Gebrauchsanleitung

Inhaltsverzeichnis
Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 98

Minimum Pulse

The minimum time in quarters of a second the auger runs in the feed by pulses. The
default value is 1.
¼
Examples: 1=
of a second
½
2=
of a second
¾
3=
of a second
4= 1 second
½
6= 1
seconds

Female Male Error

The number of Kilograms (Pounds) that each auger gives after it has been given the
command to stop. The value for the female‟s auger (auger 1) is the average error for the
last 8 batches. It is used by the system to calculate when to stop the female‟s auger so that
the amount of feed given will be accurate. The value for the males‟ auger is the maximum
error for all done batches and can be used by the user to set correctly the Advance Stop
value which should be just a few Kg (Lb) greater then this value. Both values can be
cleared by programming 0 into them.

Auger Status

This screen displays the status of the AUGER INPUT. If this input detects that any of the
augers are running, Run is displayed; if no augers are detected as running, Stop is
displayed.

Unit

Enter here 0 when the weight unit is kilogram (Kg) or 1 when the weight unit is Pound
(Lb). When the unit selected is Pound, the letters Kg are replaced by the letters Lb in all
screens.
Roxell Daybin Controller – RDC
Min. Pulse
1 [1/4 Seconds]
FemalesErr: 5 Kg
Males Err:
4.7 Kg
Auger Status
Stop
Units[0,1]
0
Kg
Page 18 of 193