COMPACT 2.0
ES
EN
Efficiency Chart Minicool Compact 2.0 - 12V
EFFICIENCY CHART MINICOOL COMPACT 2.0 - 12V
Validity:
Dirna Compact unit
Data:
To be taken with a digital thermometer
T1:
Temperature of recycled air
T2:
Temperature of blowed air. Outlet
Conditions
The cabin must be in the shade, with the doors and windows closed
The battery must be completely charged; it must be 24Vcc in the connection to the
COMPACT 2.0
The motor must be shut down
Before making the readings, leave the unit to work for at least 15 minutes
Make the readings with the two compressors running
Temperatures shall be read in ºC
One single person
The outside temperature must be equal to or under 35º
T2 (º C) Temperature of aperture output
30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9
35
5
6
7
34
4
5
6
33
3
4
5
32
2
3
4
31
1
2
3
30
1
2
29
1
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
Temperature difference between air input and output
8
9
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29
7
8
9
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
4
5
6
7
8
9
3
4
5
6
7
8
2
3
4
5
6
7
1
2
3
4
5
6
1
2
3
4
5
1
2
3
4
1
2
3
1
2
1
Good
Slightly low
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
9
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
8
9
10 11 12 13 14 15 16 17 18 19 20 21 22 23
7
8
9
10 11 12 13 14 15 16 17 18 19 20 21 22
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20 21
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20
4
5
6
7
8
9
3
4
5
6
7
8
2
3
4
5
6
7
1
2
3
4
5
6
1
2
3
4
5
1
2
3
4
1
2
3
1
2
1
24
24
Air conditioning for vehicles
10 11 12 13 14 15 16 17 18 19
9
10 11 12 13 14 15 16 17 18
8
9
10 11 12 13 14 15 16 17
7
8
9
10 11 12 13 14 15 16
6
7
8
9
10 11 12 13 14 15
5
6
7
8
9
10 11 12 13 14
4
5
6
7
8
9
3
4
5
6
7
8
2
3
4
5
6
7
1
2
3
4
5
6
1
2
3
3
5
1
2
2
4
Low
In accordance with J.I.S. Standard
8
7
6
10 11 12 13
9
10 11 12
8
9
10 11
7
8
9
10
6
7
8
9
5
6
7
8