Malfunctions and possible causes
Malfunction
Drawer or pull-out will not open
Drawer or pull-out will not open, insufficient
buffer travel
None of easys units fitted respond when
pushing or pulling on drawer
Individual easys units not working
Parallel activation of two units not working
Easys only responds after pulling or pushing
several times
Green LED not lighting up on power supply unit Plug not in power socket
Green LED flashing on power supply unit
LED not lighting up on automatic drive
LED flashing on automatic drive
On opening, drawer or pull-out travels into
limitation stop position
Several drawers or pull-outs open
simultaneously
Drawer not pushed open far enough
Drawer or pull-out not closing all the way
Possible cause
Object is obstructing drawer or pull-out
Cabinet runner incorrectly positioned
Drawer back panel deformed
Gap too small
Cabinet runner incorrectly positioned
No front panel spacer fitted
Object is obstructing drawer or pull-out
Unit plug connection from power supply unit to
plug-in distributor is not plugged in or not plugged
in properly
Connecting cable not plugged into plug-in
distributor or plugged in properly
Drawer not in easys sensing range
Easys not positioned correctly on the power rail
Unit assignment incorrectly set
System is being operated too quickly in succession
Opening travel insufficient at easys sensor
Unit plug not pushed firmly into power supply unit
Power socket switched off
System overloaded or short-circuited
Mains power not switched on
Plug connection incorrectly connected
Drive unit not fixed properly
Unit overloaded
No contact with data bus
Opening distance regulator incorrectly set on drive
unit
Cabinet not aligned horizontally
Fronts chafing against each other
Unit assignment incorrectly set
Opening distance regulator incorrectly set on drive
unit
Runner system stiff
Object obstructing drawer or pull-out
Drive unit not positioned correctly
Fronts chafing against each other
Drive unit not positioned correctly
What to do
Remove object
Position cabinet runner correctly
Straighten drawer back panel
Adjust gap alignment
Position cabinet runner correctly
Fit front panel spacer
Remove object
Properly connect plugs at plug-in distributor
Make sure plug connector is properly connected to distributor
Correctly position system in furniture carcase
Re-align easys on the power rail
Set unit assignment properly (see point 4)
Easys needs to rest for about 1.5 seconds after closing the drawer
Set front panel spacing
Make sure mains plug is plugged in properly
Make sure unit plug is properly plugged into power supply unit
Switch power socket on at the power socket switch
Disconnect all units from power supply unit and start to connect
each unit individually, checking for proper working order
Switch on mains power
Check plug connection
Set rotary knob to correct position on drive unit (see point 5)
Let unit cool down
Re-align easys on the power rail
Adjust regulator on drive unit (anti-clockwise)
Align cabinet horizontally
Adjust gap alignment
Set unit assignment properly (see point 4)
Adjust regulator on drive unit (clockwise)
Change drawer
Remove object
Change drive unit
Adjust gap alignment
Correctly position drive unit