ENGLISH
ELECTRICAL CONNECTION
Ensure that available voltage and frequency correspond to those indicated on the data plate. Ensure that
the power socket, equipped with earth/ground connection, is suitable for the rated current as per the
plate and is provided with protection according to IEC standards (magnetothermal switch with In=rated
value stated on plate. Differential with sensitivity Id=30 mA)
Check that the environment does not present any explosion danger (AD).
Check that the environment is suitable for the use of the power cable mounted on the device. The cable
mounted is for indoor environments (H05 VVF).
IMPORTANT: If the glass panel has been mistakenly placed horizontally or upside
down during transport, leave it in an upright position for at least 3 hours before con-
necting the power supply.
13