Herunterladen Inhalt Inhalt Diese Seite drucken

Possible Cause - Philips Lumea SC2007 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für Lumea SC2007:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

26
English
Rated input
Protection against electric shock
Protections rating
Operating conditions
Storage conditions temperature
Relative humidity
Operating pressure
Altitude
Emitted wavelengths
Optical exposure
Maximum optical energy
Pulse duration
Repetition time
Optical homogeneity
Troubleshooting
Problem
The device suddenly
switches off.
The device/adapter
becomes warm during
charging
I cannot use the device
from the mains.
The 'ready to flash light'
doesn't light up when I
place the attachment on
my skin, but the cooling fan
works.
This chapter summarizes the most common problems you could encounter
with the device. If you are unable to solve the problem with the information
below, visit www.philips.com/support for a list of frequently asked
questions or contact the Consumer Care Center in your country.

Possible cause

The rechargeable batteries
are empty
This is normal.
Due to safety reasons it is not
possible to use the device
from the mains.
The device and attachment
are not in proper contact with
the skin.
16 W
Class II, double insulated
IP 30 (EN 60529)
Temperature:+15 °C to 35 °C
-25 °C to 70 °C
Less than 90% (non condensing)
700 - 1060 hPa
Max. 3000 m
565 - 1400 nm, depending on attachment
2.5 - 6.5 J/cm², depending on chosen setting and
attachment
23 J
<2.0 ms
1-3.5 s, depending on chosen setting
Max. +/- 20% deviation from average optical
exposure in treatment area
Solution
Charge the device. See Chapter
Charging.
No action required.
Philips Lumea can only be used without
cord.
Adjust the pressure or angle of the
device on the skin.

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Lumea sc2009

Inhaltsverzeichnis