Données générales - Caractéristiques
Solenoid interlock monitored
Electronic manual release
Short circuit detection
Cross-circuit detection
Securing holes for Bowden cable assembly
Safety functions
Integral system diagnostics, status
Number of diagnostic signals
Number of safety contacts
Classification
Standards
Classification de sécurité - Fonction d' interverrouillage
Performance Level, up to
Category
PFH value
PFD value
Safety Integrity Level (SIL), suitable for applications in
Mission time
Classification de sécurité - Fonction de verrouillage
Performance Level, up to
Category
PFH value
PFD value
Safety Integrity Level (SIL), suitable for applications in
Mission time
Données mécaniques
Interlocking principle
Oui
Oui
Oui
Oui
Oui
Oui
Oui
2
2
EN ISO 13849-1
EN IEC 61508
e
4
1,00 x 10⁻⁹ /h
9,00 x 10⁻⁵
3
20 Year(s)
e
4
1,80 x 10⁻⁹ /h
1,60 x 10⁻⁴
3
20 Year(s)
bistable
6-35