LED signals
LED color
Continuously green
Flashing green
Continuously red
Continuously white
Continuously yellow
6
Ambient conditions
•
EMC Limit Class A (electromagnetic immunity for industrial areas)
•
Only for use indoors
•
Recommendation: ESD workstation on installation
Feature
Ambient temperature
Storage temperature
Humidity
Protection Class
DIN EN 60529
7
Troubleshooting
Problem
Accessory does not work
Application is not
loaded
10
Explanation
Measurement was successful.
Bootloader active.
→ Waiting for application.
If the LED does not stop flashing after
defective, see 7 Troubleshooting, Page 10.
Measurement has failed.
→ See Troubleshooting.
Software update is running.
Measurement is running.
Data
0 °C ... 45 °C
-25 °C ... 70 °C
10% ... 90%, non-condensing
IP40
Possible cause
Accessory not activated by software
Accessory not properly installed
Accessory defective
Tool defective
Wrong software on TIM
Wrong software on STMD-H
TIM defective
Measurement card software is not
recognized
No application on the tool
CAN bus communication not
possible
P2407MA | 2019-06
5-10
seconds, the application is
Measure
See Troubleshooting
Check installation
Replace accessory
Replace tool
Perform software update with
correct software
Perform software update with
correct software
Send tool for repair
Use correct measurement card
software
Perform software update with
correct software
Make sure the tool is installed
correctly
Make sure the correct TIM soft-
ware is used