Installing the air extraction system

Components of the air extraction system:
Component
Source
Suction
Customer
device incl.
service,
suction hose
specialist
dealers
Switching
Customer
unit
service
*
Data cable of
Manufacturer
supported
of the
suction units
suction unit
Hose connec-
Customer
tion
service
The switching unit is not available worldwide.
*

Requirements for the suction unit

Use a suction device with the following properties
only:
Designed for the commercial use in the dental
n
sector
Equipped with a filter of the filter class M
n
Suitable for the operating site of the machine
n
Equipped with safety devices which protect you
n
from static discharges (e. g. through an anti-
static suction hose)
Minimum extraction capacity: 3,500 l/min at 220
n
hPa (123.6 cfm at 3.2 psi)
Required? Prerequisite
Yes
No
Suction unit
data cable not
used
No
Supported
suction unit;
switching unit
not used
If the
suction
hose does
not fit
Original Operating Instructions:  R5
Version: 5/10/2019
R5 – Installing the machine

Installing the suction unit

You can install the suction unit as follows:
1.
Read the documentation for the suction unit. Fol-
low the operating and safety instructions at any
time.
2.
Check if the connection of the suction hose has
an outer diameter of 45  mm. If the diameter is dif-
ferent, either adjust the hose or use the optional
hose connection.
3.
Insert the suction hose of the suction unit into the
opening for the air extraction of the machine.
Ensure that the suction hose is properly seated.
F
. 14 – I
IG
NSERTING THE SUCTION HOSE INTO THE MACHINE
4.
If you want the machine to automatically switch
the suction unit on and off, choose 1 of the fol-
lowing options:
Install the switching unit (extra equipment).
n
The switching unit is not available world-
wide.
Connect a data cable provided by the manu-
n
facturer of the suction unit to the suction
unit data port of the machine. The oper-
ating manual of the suction unit should
contain additional details.
5.
Continue with the installation of the suction unit
as described in the documentation of the unit.