Operation
Figure 16 Shunting.
Lift the bar.
Figure 18 Release the bar. The locking pins
move down.
5.6
RoCo transfer
The loading procedures used when transferring loads with the RoCo are listed in ascending order
of increasing risk. Preference should be given to the transfer procedure with a lower risk.
• Same-level loading
• Stationary loading bridges or stationary lifting platforms
• Mobile lifting platforms
• Industrial trucks with lifting equipment (forklift, pallet truck, etc.)
• Lifting platforms on vehicles (tail lift)
CAUTION!
RoCos with a folded side panel or RoCo with a base which is not latched may not be picked up
by a forklift.
14/28
Figure 17 Locking pins are drawn up.
The 2 fixed castors are released and
can now move. The RoCo can now
be shunted. The handle must remain
pushed down.
Figure 19 Swivel castor can now move
for shunting.
Figure 20 As soon as the castor is in
this position, the locking pins latch
back into place.
Item no. 06.60117.BA-EN00/10.08.17